Admin > port mirroring, Admin > cable test, Admin > port mirroring admin > cable test – Linksys BUSINESS SERIES SRW224G4 User Manual

Page 65: Chapter 5, Advanced configuration

Advertising
background image

Chapter 5

Advanced Configuration

58

WebView Switches

Error

A system error has occurred.

Warning

A system warning has occurred.

Notice

The system is functioning properly, but system

notice has occurred.

Informational

Provides device information.

Debug

Provides detailed information about the

log. If a Debug error occurs, contact Customer Tech
Support.

Admin > Port Mirroring

Port mirroring monitors and mirrors network traffic by
forwarding copies of incoming and outgoing packets
from one port to a monitoring port. Port mirroring can be
used as diagnostic tool and/or a debugging feature. Port
mirroring also enables switch performance monitoring.

Admin > Port Mirroring

Network administrators configure port mirroring by
selecting a specific port to copy all packets, and different
ports from which the packets are copied.

Source Port

Defines the port to which traffic is mirrored.

Type

Indicates the port mode configuration for port

mirroring. The possible field values are:

RxOnly

Defines the port mirroring on receiving ports.

This is the default value.

TxOnly

Defines the port mirroring on transmitting

ports.

Both

Defines the port mirroring on both receiving

and transmitting ports.

Target Port

Defines the port from which traffic is

mirrored.

Admin > Cable Test

The Cable Test screen shows you results from performance
tests on copper cables. The maximum cable length that
can be tested is 120 meters. Cables are tested when the
ports are in the down state, except for the Approximate
Cable Length test.

Admin > Cable Test

Port

This is the port to which the cable is connected.

Test Result

This is the test result. OK indicates that the

cable passed the test. No Cable means there is no cable
connected to the port. Open Cable means the cable is
connected on only one side. Short Cable indicates that a
short has occurred in the cable. Undefined indicates that
the test could not be properly performed.

Cable Fault Distance

This is the distance from the port at

which the cable error occurred.

Last Update

This is the last time the port was tested.

Test

Click the Test button to perform the test.

Cable Length

This is the approximate length of the cable.

The Cable Length test can be performed only when the
port is up and operating at 1Gbps.

Advertising