u

To align the unit door in depth Z: Undo the screws

Fig. 25 (36)

at the top and the hex head screws

Fig. 25 (35)

at the bottom using the ring wrench

Fig. 25 (37)

supplied,

then move the door.

u

Do not allow the knobs and sealing lips

to come into contact with the door - im-

portant for function!

u

Set an air gap of 3/32 '' (2 mm) between

the door of the unit and the body of the

unit.

For large unit doors:

u

Fit a 3rd pair of mounting brackets

Fig. 25 (34)

.

u

Use the holes pre-drilled in the handle

area of the appliance door for this pur-

pose.

u

Check the fit of

the door and

re-adjust,

if

necessary.

u

Tighten

all

screws.

Fig. 26

u

Tighten the locknuts

Fig. 26 (32)

with the ring wrench

Fig. 26 (37)

while bracing the adjusting bolts

Fig. 26 (33)

with a screwdriver.

u

Position the upper cov-

ers

Fig. 27 (38)

and snap

into place.

u

Place the side covers

Fig. 27 (39)

in position,

slide to the limit and then

press until they snap au-

dibly into place.

u

Attach

the

covers

Fig. 27 (40)

to the side and

then draw them forward

with a screwdriver, so

that they snap properly

into place.

Fig. 27

For a 24 '' (609.6 mm) wide recess:

u

Position the covers

Fig. 9 (6,7,60)

and snap into place.

For a 23-5/8 '' (600 mm) wide recess:

u

Position the covers

Fig. 9 (5,6,7)

and snap into place.

For appliances without a stop mechanism, adjust the

opening resilience:

The opening resilience of the

door can be adjusted if necessa-

ry using the Allen wrench sup-

plied:*

u

For more spring force: Turn

clockwise.*

u

For less spring force (factory

setting): Turn counterclock-

wise.*

u

Attach the remaining covers to

the hinges.*

*

Check the following points to ensure that the appliance has

been installed correctly. Incorrect installation can cause

icing up, the formation of condensate, and malfunctions:
w

The door must close properly.

w

The door of the unit must not touch the body of the unit.

w

The seal at the top edge on the handle side must fit tightly.

To verify this, darken the room, place a flashlight inside

the appliance near the top, and close the door. If you see

light shining through, check the assembly.

7 Connecting the appliance

WARNING

Electrical shock hazard!

u

Start-up should only take place once the appliance has

been installed according to these instructions.

u

Electrically ground appliance.

u

Do not ground to a gas pipe.

u

Check with a qualified electrician if you are not sure the

appliance is properly grounded.

u

Do not have a fuse in the neutral or grounding circuit.

u

Do not use an extension cord or a multiple socket.

u

Do not use a power cord that is frayed or damaged.

WARNING

Electrical shock hazard!

This appliance is equipped with a three-prong (grounding)

polarized plug for your protection against possible shock

hazards. Electrical Grounding Required.

u

Do not remove the round grounding prong from the plug.

u

Do not use a two-prong grounding adapter.

- Wait 30 minutes up to 1 hour after installation before you

plug in the appliance. This allows the refrigerant and sys-

tem lubrication to reach equilibrium.

- Make sure incoming voltage is the same as the appliance

rating. A 110-120 Volt, 60 Hz, 15 Amp electrical supply

(20 Amp for side-by-side installations) circuit that is con-

trolled by a circuit breaker or fuse is required.