Leviton Plug-In Serial Interface Module RZCP User Manual

Plug-in serial interface module, Installation instructions

Advertising
background image

Plug-In Serial Interface Module

Cat. No. RZCØP

Rated: 120VAC, 60Hz

INStallatIoN INStRuCtIoNS

DI-000-RZC0P-00C

INtRoDuCtIoN

Leviton’s Vizia

TM

RF components are designed

to communicate with each other via Radio

Frequency (RF) to provide remote control

of your lighting. Using RF technology allows

Leviton to provide the greatest signal integrity

possible. Each module in Leviton’s Vizia

TM

RF component line is a Z-Wave

TM

enabled

device. In a Z-Wave

TM

network, each device is

designed to act as a router. These routers will

re-transmit the RF signal from one device to

another until the intended device is reached.

This ensures that the signal is received by its

intended device by routing the signal around

obstacles and radio dead spots. The Plug-in

Serial Interface Module is compatible with any

Z-Wave™ enabled network, regardless of the

manufacturer and can also be used with other

devices displaying the Z-Wave™ logo.

CautIoN:

Remember to exercise good common sense

when using the Timer features of your remote,

especially when scheduling unattended

devices. There can be some unexpected

consequences if not used with care. For

example, an empty coffee pot can be remotely

turned on. If that should happen, your coffee

pot could be damaged from overheating. If an

electric heater is turned on by remote control

while clothing is draped over it, a fire could

result.

Including Plug-In Serial

Interface Module into Z-Wave

tM

Network:

Step 3

attaching Plug-In Serial

Interface Module to Wall

Receptacle:

Step 2

attaching Serial-RS232 Cable

or HaI Cable to Plug-In Serial

Interface Module:

Step 1

NotE: In order to use your Vizia

TM

Plug-In Serial

Interface Module in a Z-Wave

TM

network, it must

be Included into the network using a Primary

Programmer/Remote, such as Leviton’s Cat.

No., RZCPG. Before Including your module,

please refer to the Primary Programmer/Remote

instruction sheet for complete information. Refer

to Step 3 for further details.

NotE: Use check boxes when Steps

are completed.

INStallING YouR INtERFaCE MoDulE

RS232 cable

to CPU

HAI cable

to HAI controller

RS232 cable to

Interface Module

HAI cable to

Interface Module

OR

WaRNINGS aND CautIoNS:

• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.

WaRNINGS aND CautIoNS:

• Save this instruction sheet. It contains important technical data along with testing

and troubleshooting information which will be useful after installation is complete.

• RS232 - ASCII
• Scene capable
• Two way communication
• RF reliability
• Ease of installation – No new wiring
• Compatible with other Z-Wave™ enabled

devices

NotE: This product requires the use of

third party software to function, along with a

relatively high level of programming skill.

FEatuRES

Step 3 cont’d

Programming

Button

1

ON

2

ON

3

ON

4

ON

OFF

OFF

OFF

OFF

Programmer/Remote

Cat. No. RZCPG

Center Button

Menu Button

Compatible with

enabled products!

TM

NotES:
• If using a non-Leviton Programmer/Remote,

refer to the Programmer/Remote instruction

sheet.

• Plug-In Serial Interface Modules included into

a Z-Wave

TM

network must be updated after you

have included all other devices.

a) If using a Leviton Z-Wave

TM

Programmer/

Remote, Cat. No. RZCPG, press the Menu

button and scroll down to System Setup. Press

the center button to select System Setup Menu.

Press the center button to select Network.

Press the center button to <Include Node>.

B) If using RZCPG Programmer/Remote, you will

be prompted to prepare device for inclusion. To

do this you must put the Plug-In Serial Interface

Module into programming mode.

C) To access Program mode, press and hold

programming button until the LED turns Amber.

You are now in Programming mode.

NotE: If the LED on the Plug-In Serial

Interface Module turns solid Red while

including, there has been a communication

error.

D) While standing close to the Plug-In Serial

Interface Module (approximately 2-5 ft.), press

the center button on the Programmer/Remote

to <Include> device in the network. NotE:

Only one device may be included at any time.

E) The Primary Programmer/Remote will

assign a Home ID, Node ID, and Name for

this device.

NotE: This information will be stored in the

Programmer/Remote to be used for future

reference.

NotE: You may name or edit the node of

this device at this time.

F) the Plug-In Serial Interface Module is

now installed in the network.

G) After all devices are included into the

network, the Plug-In Serial Interface

Module must be updated to allow proper

network function. To update Plug-In Serial

Interface Module proceed as follows:

• If using a non-Leviton Programmer/

Remote, refer to the Programmer/

Remote instruction sheet for updating

Plug-In Serial Interface Module.

• If using Leviton Z-Wave

TM

Programmer/

Remote, Cat. No. RZCPG, press the

Menu button and scroll down to System

Setup. Press the center button to select

System Setup Menu. Press the center

button to select Network. Press the

center button to select Update "cntrl".

When prompted, press button on the

Plug-In Serial Interface Module.

• Wait until the RZCPG Programmer/

Remote confirms completion. Update

is done.

NotE: If the Plug-In Serial Interface Module

has been successfully Included in the

network and the user tries to Include it again

without first excluding it from the network, the

controller will retain the first node ID it had

received and ignore the second.

• Attach RS232 cable to Plug-

In Serial Interface Module

and CPU.

oR
Attach HAI cable to Plug-In

Serial Interface Module and

HAI controller.

• Plug the Plug-in

Serial Interface

Module into wall

receptacle. Verify

that receptacle is

live. If controlled

by a wall switch,

the switch must

be kept oN at all

times.

Advertising