Fireplace specifications - model mp-42od figure 18, Outside chase - indoor installations – LG MP-42OD User Manual

Page 9

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

9

45"

(1143 mm)

31-9/16"

(802 mm)

21-1/4"

(540 mm)

8-3/16"

(208 mm)

Top View

Right Side

Gas Line

Access

Junction

Box

Combustion

Air Inlet

9-7/8"

(251 mm)

43"

(1092 mm)

21-1/4"

(540 mm)

43"

(1092 mm)

21-1/4"

(540 mm)

Left Side

45"

(1143 mm)

Front View

43"

(1092 mm)

7-3/16"

(183 mm)

41"

(1041 mm)

2"

(51 mm)

12-1/2"

(318 mm)

22-5/16"

(566 mm)

13-7/16"

(341 mm)

8-3/8"

(213 mm)

Fireplace Top Spacer

Fireplace

Top Spacer

Gas Line

Access

19"

(483 mm)

10"

(254 mm)

12

¹⁄₂"

(318 mm)

47"

(1194 mm)

1"

(25 mm)

38"

(965 mm)

FIREPLACE SPECIFICATIONS - MODEL MP-42OD

Figure 18

Notes

Due to Lennox' ongoing commitment to quality,
all specifi cations, ratings and dimensions are
subject to change without notice.

All framing dimensions calculated for 1/2" dry wall
at the fi replace face. If sheathing the chase or
fi nishing with other thickness materials, calcula-
tions will need to be made.

See Page 10 for Ceiling and Roof Framing
Dimensions

Diagrams & Illustrations Not to Scale

Fireplace Framing

Header

(See Note **)

B

1

A

B

2

A

Outside Chase

G

C

H

Including Finising Materials

if any

Rough

Framing Face

(Unfinished Shown)

Combustion

Air Kit - Optional

*

Framing Dimensions

A

46-1/2"

1181 mm

B

1

43-1/2"

1105 mm

B

2

60-1/2"

1537 mm

C

33"

828 mm

D

17-1/2"

445 mm

E

76-1/4"

1937 mm

F

38-1/8"

968 mm

G

21-5/8"

549 mm

H

20-5/8"

524 mm

J

53-7/8"

1362 mm

K

8"

203 mm

Outside Chase - Indoor Installations

Outside

Air Kit

G

A

Outside Chase

Back Wall of Chase/Enclosure
Including Finishing
Materials if any

Rough Framing Face
(Unfinished Shown)

Optional

Drainage

Line

**Note: When Framing With 6” Studs Header Must Be 17”
(432mm) Higher. Use Security Chimney’s OR15 Offset/Re-
turn Elbow To Recess The Chimney Back 2 1/2” (64mm).
Flat Frame Down To A False Header At (B

1

). Maintain

Required Clearance To Chimney At All Times.

* 1" Air Space to insulation and construction materials on the
back and sides.

OTL Report No. 116-F-37-2

Corner Installation

J

D

A

E

F

Back Wall of

Chase/Enclosure

Including Finising

Materials

if any

Rough
Framing Face
(Unfinished Shown)

OAK-OD Combustion

Air Kit

A

K

G

Inside Chase

Back Wall of Chase/Enclosure

Including Finishing Materials, if any.

Rough

Framing Face

(Unfinished Shown)

OAK-OD Combustion
Air Kit

Product Reference Information

Cat.

No.

Model

Ship.

Weight

Ship.

Volume

H1934

MP-42OD

188 lb.

24 cu. ft.

Advertising