7-1 FUNCTION

7-1-1 Function

1. When the appliance is plugged in, it is set to "3" for the Refrigerator.

You can adjust the Refrigerator control temperature by pressing the ADJUST button.

2. When the power is initially applied or restored after a power failure, it is automatically reset to "3".

7-1-2 Defrost Cycle

1. A defrost cycle will be initiated after 4 hours of accumulated compressor run time after the initial power up or a power

failure.

2. After the initial defrost, the defrost cycle is initiated after 7 hour of accumulated compressor run time.

3. The defrost cycle will be terminated once the defrost sensor reaches 50°F(10°C).

7-1-3 Electrical Parts Operates in Orders

Electrical parts such as COMP, defrost heater, freezer FAN, etc. operate in the following order to prevent noise and parts
damage. Several parts are started at the same time at initial power on and are turned off together when TEST is
completed.

7. DESCRIPTION OF FUNCTION & CIRCUIT OF MICOM

- 16 -

WARMER

COLDER

1

2

3

4

5

TEMPERATURE

ADJUST

OPERATING

ORDERS

Temperature of Defrost
Sensor is 113°F(45°C) or
more (when unit is newly
purchased or when moved)

Temperature of defrost
sensor is lower than
113°F(45°C) (when power
cuts, SERVICE)

Reset to normal operation
from TEST MODE

Initial power on

POWER

ON

in 1/2 second

Total load

OFF

COMP &

Freezer FAN

ON

in 7 minute

COMP &

Freezer FAN

ON

POWER

ON

COMP &

Freezer FAN

ON

Defrost

heater ON

Defrost

heater OFF

in 1/2 second

in 1/2 second

in 10 second