Detail a – Lennox Hearth Shoreline 33/40 DV INS User Manual

Page 22

Advertising
background image



NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE

Shoreline™ Main Burner Operation

Your Shoreline fireplace insert comes with an “ON/OFF” rocker switch

used to turn the burner on and off while the pilot is on. The rocker switch

is located in the control panel above the blower rheostat switch and to the

left of the igniter. This is all located behind the right side surround.

A wall-mounted switch, a millivolt wall thermostat, or a remote control,

can be used to supplement the rocker switch. The gas valve is powered

by millivolts generated by the pilot assembly. This millivolt system is very

sensitive to electrical resistance, therefore, make sure all connections are

tight, clean, and free from corrosion. Do not splice any millivolt wires.

Consult Table 12 to determine the proper gage of wire for the thermostat

or wall switch connections. This chart refers to the total length of the wire

(out to the switch and back). The thermostat must be a millivolt type.

A 24-volt furnace thermostat will not work. Never hook up household

current - 120 Volts - to the millivolt system. It is not recommended to

hook up any more than two switches to the fireplace insert (for example

a rocker switch and a wall thermostat). Additional switches may affect

the system resistance and increase the chance of the burner not igniting.

Follow the instructions included with the thermostat or remote control

for wiring.

The thermostat, remote control, and rocker switch will turn the burner

on and off independently. Be sure to set the rocker switch to the “OFF”

position when using the thermostat or remote control and set the ther-

mostat or remote control to the lowest temperature when you wish to

use the rocker switch only, otherwise one may override the other. If a

remote thermostat is to be used with the insert, do not place the receiver

under the firebox.

Care should be taken to ensure any installed wires from thermostat do

not come in contact with the hot surfaces of the firebox.

IMPORTANT NOTE: If a wall thermostat is to be installed, install the

thermostat per the manufacturers instructions, provided with the ther-

mostat. Failure to follow manufacturers instructions could result in a

malfunction. Pay special attention to the thermostat location require-

ments. If the location requirements are not adhered to the appliance,

erratic operation or failure may occur. Do not mount the thermostat

where it may be affected by:

• Radiant heat from the stove, fireplaces, sun or other heat

sources.

• Drafts or dead spots behind doors or in corners.

• Hot or cold air from ducts.

Thermostat Wire

Wire Size

Maximum Length

1 Gage

100 Feet

14 Gage

64 Feet

16 Gage

40 Feet

18 Gage

5 Feet

0 Gage

16 Feet

Table 12

Millivolt Control System

This Shoreline fireplace insert operates on a millivolt control system.

As such, no additional power supply is needed for the Shoreline insert

to heat. The pilot assembly contains a thermocouple, that when heated

by the pilot flame, generates electricity (millivolts- mV=1/1000 of a volt)

which opens a valve allowing gas to flow to the pilot assembly. The

pilot assembly also contains a thermopile, that when heated by the pilot

flame, generates electricity that flows to terminal #1 (labeled TH/TP)

on the gas valve. When the electricity is conducted from terminal #1

through the on/off switch, thermostat, or receiver of the remote control

to terminal #3 (labeled TH) on the gas valve, the main burner will ignite.

See Figures 37 and 38.

PILOT

OFF

ON

HI

LO

PILO

T

TPTH

TP

TH

1

2

3

Figure 37 Millivolt Wiring Diagram

Gas Valve

Thermopile

Inlet Pressure Tap

ON/OFF Switch

(Burner)

ON/OFF switch or thermo-

stat - Connect to terminal

3 on gas valve

Pilot Hood

Igniter (sparker)

Thermocouple

Pilot Assembly

Pilot Tube

Piezo Igniter

Manifold Pressure Tap

Gas Inlet

Pilot/On/Off Gas

Control Knob

Flame Height (HI/LO)

Detail A - See

Figure 38

ON/OFF switch or thermostat -

Connect to terminal 1 on gas valve

DETAIL A

PILOT

OFF

ON

HI

LO

PILO

T

TPTH

TP

TH

1

2

3

To optional

remote or

thermostat

To Thermopile

To ON/OFF

Switch

Figure 38

Gas Valve

Refer to Figure 37

Pilot Adjustment Screw

NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE

Advertising