Lennox Hearth Shoreline 33/40 DV INS User Manual

Page 4

Advertising
background image

4

NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE

Millivolt Models with Manually-Modulated Gas Valves

Natural Gas

Propane (LP) Gas

Model

Input Rate

(BTU/HR)

Input Rate

(BTU/HR)

SHR33

19,500 to 33,000

19,500 to 33,000

SHR40

4,000-40,000

1,500 to 37,500

Table 1

Note: These appliances are designed as supplemental heaters. There-

fore, it is advisable to have an alternate heat source when installed in a

dwelling.

Millivolt Valve & Electrical

These appliances use a millivolt type control system consisting of a gas

control valve with regulator (control to adjust for flame appearance and heat

output), a standing pilot burner assembly, a thermopile, thermocouple, a

piezo igniter, and ON/OFF switch.

THE GAS BURNER SYSTEM ON THESE

APPLIANCES DO NOT REQUIRE 10 VOLT POWER TO OPERATE. Because

this fireplace insert is operated with a millivolt valve it will burn even

during a power outage.

The Shoreline features a spark igniter (piezo) that allows the appliance's

pilot gas to be lit without the use of matches or batteries. However, the heat

circulation blower motor requires 120 Volts AC (the appliance can be safely

used with the blower turned off). The blower operation is controlled by a

variable speed rheostat.

These appliances may be installed in an aftermarket permanently

located, manufactured home (USA only) or mobile home, where not

prohibited by local codes.

Cet appareil peut être installé dans un maison préfabriquée (É.-U.

seulement) ou mobile déjà installée à demeure si les réglements

locaux le permettent.

CODES AND APPROVALS

Table 2 shows efficiencies for the Shoreline™.

GENERAL INFORMATION

Table 1 shows the BTU input for each model:

Fuel

This insert comes from the factory equipped to burn natural gas from 0

to 2,000 feet (610 M) of elevation in the USA and 0 - 4,500 feet (1372

M) in Canada. The insert can be converted to burn LP (liquid propane)

by installing a conversion kit. Only Lennox Hearth Products conversion

kits can be used to convert from NG to LP or LP to NG. Contact your

Lennox Hearth Products dealer for details. An orifice is also supplied to

change the unit from 40,000 BTU’s (NG) or 37,500 BTU’s (LP) to 33,000

BTU’s. This must be done by a qualified service technician if you decide

to change orifices.

The use of other fuels or combination of fuels will degrade the performance

of this system and may be dangerous.

Orifice Size/Altitude Adjustment

These appliances are tested and approved for installations at elevations

of 0 to 2,000 feet (610 M) in the USA and 0 to 4,500 feet (0-1372 M) in

Canada using the factory installed orifice shown in Table 3. At higher

elevations the BTU input must be de-rated by 4% for every 1,000 feet

(305 M) to maintain the proper ratio of gas to air. Contact your local gas

supplier for deration requirements for your area.

Deration - At higher elevations, the amount of BTU fuel value delivered

must be reduced by either using gas that has been derated by the gas

company or by changing the burner orifice to a smaller size as regulated

by the local authorities having jurisdiction and by the (USA) National

Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition or, in Canada,

the CAN/CSA B149.1 - latest edition. If it is determined that a smaller

burner orifice is needed, contact your Lennox Hearth Products dealer to

purchase the orifice.

Burner Orifice Sizes

USA - Elevation 0-000 feet ( 0-610 meters)

Canada - Elevation 0-4500 feet ( 0-137 meters)

Model

Natural Gas

drill size (inches) *

Propane

drill size (inches) *

SHR33

#36 (0.1065”)

#51 (0.067”)

SHR40

1/8” (0.15”)

#49 (.073”)

Table 3

* Standard size installed at factory

Listing and Safety Standards - Gas appliances must be tested and certi-

fied by a nationally recognized testing and certification laboratory to ANSI

(American National Standard Institute) gas appliance safety standards.

This insert has been tested and certified by OMNI -Test Laboratories to

ANSI Z21.88-2005/CSA 2.33-2005 “Vented Gas Fireplace Heaters and

CGA 2.17-M91 “Gas-Fired Appliances for Use at High Altitudes” and UL

307B Gas Burning Heating Appliances for Manufactured (Mobile) Homes

in both USA and Canada. These appliances have been certified for use

with either natural gas or propane and are approved for installation in

sitting rooms and/or bedrooms.

This appliance is only for use with the

type of gas indicated on the rating plate (and is not for use with solid

fuels). This appliance is not convertible for use with other gases,

unless a certified kit is used.

Cet appareil doit être utilisé uniquement avec les types de gaz indiqués

sur la plaque signalétique. Ne pas l'utiliser avec d'autres gaz sauf si

un kit de conversion certifié est installé.

Efficiencies %

Natural Gas

Propane

Models

P4**

Steady

State*

AFUE

P4**

Steady

State*

AFUE

SHR33

60.91

83

60

64.35

83

65

SHR40

6.70

83

63

65.98

83

67

* The Steady State Efficiency numbers based on maximum vent configuration.

** Tested to CSA P.4.1-02 “Testing Method for Measuring Annual Fireplace Efficiency.

Table 2