Lennox Hearth Shoreline 33/40 DV INS User Manual

Page 8

Advertising
background image

8

NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE

A

B

C

D

E

F

G

H

I

CL

Figure 2 - Existing Fireplace Minimum Dimensions

Figure 3 - Minimum Clearances

Combustibles Trim or Mantel Depth of 8” or Less

Hearth Protection

Mantel - 1” Depth

Minimum Fireplace Dimensions

and Minimum Clearances

Inches

(millimeters)

A

Minimum front opening required

36 (914)

B

Minimum height required

1-1/ (546)

C

Minimum rear width required

19-1/ (495)

D

Minimum fireplace depth required

16 (406)

E

Clearance needed from bottom of insert to com-
bustibles or 8” mantel

35 (889)

F

Clearance required from center of glass to com-
bustible material

30 (76)

G

Minimum inches of hearth protection needed from
front of unit

1 (305)

H

Vertical clearance needed under the bottom of the
insert for NO hearth protection

8 (03)

I

Clearance needed from bottom of insert to 1”
mantel

38 (965)

Table 4

Refer to Table 4

Refer to Table 4

Refer to Figures 2 through 4

These appliances can be installed in most fireplace configurations. If

installed close to an adjacent wall, ensure that the minimum clearances

to combustible surfaces are maintained. A local building inspector

should review your plans prior to installation.

Refer to Figures 2 through 4 for clearances to combustibles. Minimum

clearances include any projections such as shelves, window sills, mantels,

spacers/standoffs or surfaces to combustible construction etc. above the

appliance. Paint or lacquer used to finish the mantel must be heat resistant

in order to avoid discoloration.

Examples:

Hearths that are level with the base

of the insert require 1” minimum of

forward hearth protection.

Hearths that are elevated 8” minimum

above combustible floor require 0” of

forward hearth protection.

G

H

Combustible Floor

Figure 4 - Hearth Protection

G

H

H dimension deter-

mines G minimum

0”

8”

1-1/”

7”

3”

6”

4-1/”

5”

6”

4”

7-1/”

3”

9”

”

10-1/”

1”

1”

0”

Hearth Protection

Fireplace Firebox

Insert

MINIMUM CLEARANCES TO COMBUSTIBLES

Hearth / Floor Protection Requirements

The hearth and/or floor protection must be a thermally rated hearth/floor

protector meeting or exceeding a thermal rating of k = .84 (or lower) or

r= 1.19 (or higher) with a listed thickness of 1" minimum. If an hearth

extension is used, check with the manufacturer for the listed thermal rating

of the hearth extension to ensure it meets the thermal requirements of k

= .84, r= 1.19, listed thickness 1". If a custom hearth or floor protection

is planned, see NFI (National Fireplace Institute) certification manuals

showing methods for calculating minimum thicknesses and approved

fireplace hearth/floor protection materials.