TERMINALS

10MM

BOLTS

DC-

DC+

FIGURE F.13 – INVERTER BOARD REMOVAL

INVERTER BOARD REMOVAL AND REPLACEMENT PROCEDURE (CONTINUED)

7. Using a 10mm nutdriver with extension, remove the

two bolts mounting the inverter board to the positive

(+) and negative (-) leads that connect to the output

terminals on the front ot the macine. See Figure

F.13

Note: One 10mm mounting bolt can be accessed from

the soldered side of the inverter board. The

other bolt must be accessed from the left side of

the machine using the socket extension. Note

washer placement for reassembly,

8. Label and disconnect any associated plugs and

leads.

9. Remove the inverter board.
10. Connect JP 1 connector and make sure that the

upper front corner of the board is in the locator slot

of the front panel.

11. Be sure that the white lead is re-connected to the

Positive Input terminal.

12. Re-connect the red and black leads to the DC+ and

DC- points on the Inverter Board.

13. Re-install the Inverter to the case, making sure the

ground lead is re-connected to the lower front cor-

ner.