Installation, Select suitable location, Output connections – Lincoln Electric WELD-PAK 3200HD User Manual

Page 10

Advertising
background image

A-3

INSTALLATION

WELD-PAK 3200HD

A-3

4

5

8

3

6

7

1

2

+

-

FIGURE A.2

Work Clamp Installation

Attach the work clamp per the following:

1. Unplug the machine or turn the power switch to the

OFF

position.

2. Insert the work cable terminal lug with the larger

hole through the strain relief hole in the work clamp
as shown in Figure A-3.

3. Fasten securely with the bolt and nut provided.

FIGURE A.3

SELECT SUITABLE LOCATION

Locate the welder in a dry location where there is free
circulation of clean air into the louvers in the back and
out the front of the unit. A location that minimizes the
amount of smoke and dirt drawn into the rear louvers
reduces the chance of dirt accumulation that can block
air passages and cause overheating.

STACKING

WELD-PAK 3200HD cannot be stacked.

TILTING

Each machine must be placed on a secure, level sur-
face, either directly or on either recommended cart.
The machine may topple over if this procedure is not
followed.

OUTPUT CONNECTIONS

Refer to Figure A.2.

1. Work Cable Access Hole.

2. Gun Cable and Control Lead Access Hole.

3. Connector Block.

4. Gun Trigger Lead Connectors.

5. Positive (+) and negative (

) output terminals.

6. Wire Feed Gearbox.

7. Cable Hanger.

8. Thumbscrew.

Strain Relief Hole

Nut & Bolt

Work Clamp

Work Cable

Advertising