Rs-232c terminal, Rs-232c remote operation method, Remote specifications – Panasonic BT-LH2600WE User Manual

Page 31: Continued)

Advertising
background image

31

REMOTE Specifications

(continued)

g Assignment of item priority levels

• When both “MARKER1” and “MARKER2” are ON at the same time, “MARKER1” has priority. However, when the

display aspect is 4:3, the “MARKER1” aspect is 16:9, and the “MARKER2” aspect is 4:3, “MARKER2” is
displayed. In this case, the “MARKER2” background is controlled.

• When “MARKER BACK HALF” and “MARKER BACK BLACK” are simultaneously activated, priority goes to

“MARKER BACK BLACK”.

• When two or more of the following items - “INPUT SEL. VIDEO”, “INPUT SEL. Y/C”, “INPUT SEL SDI1”, “INPUT

SEL. SDI2” and “INPUT SEL. YP

B

P

R

/RGB” - are simultaneously activated, priority goes to the last item activated.

• When “GAMMA SEL. FILM” and “GAMMA SEL. STDIO/PST” are simultaneously activated, priority goes to

“GAMMA SEL. FILM”.

Refer to the following diagram and lower right table for the RS-232C terminal pin arrangement and connections.
Please contact the vendor for information about detailed systems which used the RS-232C.

g Connectors and signal names

Connector: D-SUB 9-pin (female)
Signal name

g Communication Conditions

g Command format

Commands are 3 characters following STX, finally

adding ETX.

Add a : (colon) after the command as required, and

add the data.

g Response formats

1. Setting command response

2. Query command response

3. Error response

Error code
ER001: Invalid command
ER002: Parameter error

RS-232C terminal

PC Side

(Straight)

BT-LH2600W Side

Pin number

Signal

Pin number

Signal

1

N.C.

1

N.C.

2

RXD

2

TXD

RS-232C Terminal (9P)

3

TXD

3

RXD

4

DTR

4

DSR

5

GND

5

GND

6

DSR

6

DTR

7

RTS

7

CTS

8

CTS

8

RTS

9

N.C.

9

N.C.

RS-232C REMOTE operation method

Pin

number

Signal

name

Explanation

1

N.C.

Not connected

2

TXD

Transmission data

3

RXD

Reception data

4

DSR

Connected inside.

5

GND

Ground

6

DTR

Connected inside.

7

CTS

Connected inside.

8

RTS

Connected inside.

9

N.C.

Not connected

Signal level

Conforms to RS-232C

Synchro system

Tone pace synchro system

Transfer rate

9600 bps

Parity None
Data length

8 bit

Stop bit

1 bit

Flow control

None

STX (02h)

Command

:

Data

ETX (03h)

STX (02h)

Command

ETX (03h)

STX (02h)

Data

ETX (03h)

STX (02h)

Error code

ETX (03h)