Panasonic CS-E9GFEW-2 User Manual

Page 5

Advertising
background image

5

1. Cooling capacities are based on indoor temperature of 27

°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)

and outdoor air temperature of 35

°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)

2. Heating capacities are based on indoor temperature of 20

°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry

Bulb (44.6

°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)

Note

• Specifications are subject to change without notice for further improvement.

Fan

Type

Turbo Fan

Propeller Fan

Material

ASG

PP

Motor Type

Transistor (8-pole)

Induction (6-pole)

Input Power

W

66.0 - 74.1

Output Power

W

48

25

Fan Speed

QLo (Cool/Heat)

rpm

360 / 360

Lo (Cool/Heat)

rpm

410 / 410

Me (Cool/Heat)

rpm

510 / 520

Hi (Cool/Heat)

rpm

620 / 630

745 - 790 / -

SHi (Cool/Heat)

rpm

660 / 670

Heat Exchanger

Fin Material

Aluminium (Pre Coat)

Aluminium (Pre Coat)

Fin Type

Slit Fin

Corrugated Fin

Row x Stage x FPI

2 x 22 x 19

2 x 24 x 17

Size (W x H x L)

mm

510 x 396 x 24

36.4 x 504 x 713

684

Air Filter

Material

PET

Type

Honeycomb

Item

Unit

Power Source (Phase, Voltage, Cycle)

ø

Single

V

220 - 240

Hz

50

Input Power

W

Cooling; 570 (175 ~ 780)

Heating; 865 (165 ~ 1360)

Starting Current

A

4.20

Running Current

A

Cooling; 2.75 - 2.65

Heating; 4.20 - 3.90

Maximum current

A

6.15

Power Factor

%

Cooling; 94 - 90

Heating; 94 - 92

Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.

Power Cord

Number of core

Length

m

Thermostat

Electronic Control

Protection Device

Electronic Control

ITEM

UNIT

INDOOR UNIT

OUTDOOR UNIT

Advertising