TABLE 3

The codinf value transmitted by the PST during any kind of acknowledge/alarm call is assigned a particular status in the FCP. This TABLE
lists the codinf digit and status of the each in the FCP.

CODINF
DIGIT

FUNCTION

0

The alarm LED status is updated to “no move switch off”
When no acknowledge is expected, then “call desk function will be activated when FCP set for “call panel.1”
When acknowledge is expected, the call will be accepted as the auto acknowledge reply

1

The alarm LED status is updated to “no move switch off”
The “call desk” function will be activated, when the FCP is set for “call panel 2”
When acknowledge is expected, the “call dek” will be accepted as the auto acknowledge reply

2

The alarm LED status is updated to “no move switch on”
When no acknowledge is expected, then “call desk function will be activated when FCP set for “call panel.1”
When acknowledge is expected, the call will be accepted as the auto acknowledge reply

3

The alarm LED status is updated to “no move switch on”
The “call desk” function will be activated, when the FCP is set for “call panel 2”
When acknowledge is expected, the call will be accepted as the auto acknowledge reply

6

The alarm LED status is updated to “no move alarm” (constantly lit)
The constantly lit function of the alarm LED has the highest priority
When acknowledge is expected, the call will be accepted as the auto acknowledge reply
to activate the “call panel 1” function”, the PST should be reset first

4

5

7

9

These calls are ignored

B

D

and

F

CALL PANEL FUNCTION

The desk will send all received field calls with no 5-digit info to the FCP

When the call is located in the acknowledge call address table of the FCP then the FCP will interpret this
as a panel call if:

0 and 2

No auto acknowledge call waiting - the page line is not at code level and the time between the last code line
level and the field call > 1

1 and 3

Channel status ignored