For . . .

Enter . . .

Severely Error
Seconds

A number from 0 to 900, or a D for Disable
(Default = 15).

If the number of DSL Severely Errored Second events
equals or exceeds the selected number within a 15-minute
period, an SNMP trap is sent. If set to Disable or 0, no
Severely Errored Seconds trap is ever sent. If set to 1, a
trap is sent after each Severely Errored Seconds event.

Unavailable Seconds

A number from 0 to 900, or a D for Disable
(Default = 1).

If the number of DSL Unavailable Second events equals or
exceeds the selected number within a 15-minute period, an
SNMP trap is sent. If set to Disable or 0, no Unavailable
Seconds trap is ever sent. If set to 1, a trap is sent after
each Unavailable Seconds event.

Loss of Sync Word
Seconds

A number from 0 to 900, or a D for Disable
(Default =1).

If the number of Loss of Sync Word Seconds events equals
or exceeds the selected number within a 15-minute period,
an SNMP trap is sent. If set to Disable or 0, no Loss of
Sync Word Seconds trap is ever sent. If set to 1, a trap is
sent after each Loss of Sync Word Seconds event.

CRC Anomaly
Threshold

A number from 0 to 900, or a D for Disable
(Default =1).

If the number of Cyclical Redundancy Check (CRC) events
equals or exceeds the selected number within a 15-minute
period, an SNMP trap is sent. If set to Disable or 0, no CRC
Anomalies trap is ever sent. If set to 1, a trap is sent after
each CRC anomaly event.

SNR Margin Threshold

A number from 0 to 15 (Default = 0).

If the Signal-to-Noise (SNR) ratio (in dB) reaches or drops
below the selected value, an SNMP trap is sent.

Attenuation Threshold

A number from 0 to 127 (Default = 0).

If the Attenuation reaches or drops below the selected
value, an SNMP trap is sent.

Link Down Count

A number from 0 to 900, or a D for Disable
(Default = 0).

If the number of DSL Link Down events exceeds the
selected number within a 15-minute period, an SNMP trap
(Enterprise trap xdslLinkUpDownTransitions(1)) is sent. If
Link Down Count is set to Disable or 0, no Link Down trap
is ever sent. If set to 1, a trap is sent after each
linkUpDownTransition event.