5. Diagnostics

5-10

February 2003

8335-A2-GB20-70

Card Alarms Screen – Model 8385

(Continued)

D-B

Minor Alarms:

Config Error – If ALARM appears on this line, the card has detected a checksum error in
the memory where the configuration is stored.

Loss of Cell Delineation – If a loss of cell delineation has been detected on the port, an
A (for Alarm) appears in the column for that port.

Loss of Signal – If a loss of signal has been detected on the port, an A (for Alarm)
appears in the column for that port.

Error Seconds –The number of Errored Seconds has exceeded the user-defined
threshold.

Severely Errored Seconds – The number of Severely Errored Seconds has exceeded
the user-defined threshold.

Unavailable Seconds – The number of Unavailable Seconds has exceeded the
user-defined threshold.

Loss of Sync Word Second – The number of Loss of Sync Word (LOSW) seconds has
exceeded the user-defined threshold.

CRC Anomalies Threshold – The number of CRC anomalies has exceeded the
user-defined threshold.

SNR Margin Threshold – The SNR margin has exceeded the user-defined threshold.

Attenuation Threshold – The current value reached or dropped below the user-defined
threshold.

Repeater Segment Down – One of the repeater segments is down.

SN Loss of Power – The endpoint has lost power.

CAC Exceeded – The DSL line rate has dropped below the traffic contract. The traffic
contract has exceeded the available bandwidth making the contract invalid.