Power connector, Ethernet port (outlined in green), Mdi-x – Patton electronic PATTON 2603 User Manual

Page 22: Ac universal power supply 48 vdc power supply, Ethernet port (outlined in green) mdi-x, Ac universal power supply, 48 vdc power supply

Advertising
background image

IPLink Series High Speed Routers overview

22

Models 2603, 2621, and 2635 Getting Started Guide

1 • General Information

Power input connector

Ethernet connector

MDI-X switch

WAN port (V.35, X.21, T1/E1)

Power connector

AC universal power supply.

The IPLink Series router offers internal or external AC power supply options.

The internal power supply connects to an AC source via an IEC-320 connector (100–240 VAC, 200 mA,
50/60 Hz)

The external power supply connects to an external source providing +5 VDC via a barrel-type connector

48 VDC power supply.

The DC power supply connects to a DC source via a terminal block

Rated voltage and current: 36–60 VDC, 400 mA

Ethernet port (outlined in green)
Shielded RJ-45 10Base-T/100Base-TX Ethernet port using pins 1,2,3, & 6. See MDI-X switch for hub or trans-
ceiver configuration.The following table defines conditions that occur when the MDI-X switch is in the out position.

MDI-X
The MDI-X push switch operates as follows:

When in the default “out” position, the Ethernet circuitry takes on a straight-through MDI configuration
and functions as a transceiver. It will connect directly to a hub.

When in the “in” position, the Ethernet circuitry is configured in cross-over MDI-X mode so that a
straight-through cable can connect The IPLink Series router’s Ethernet port directly to a PC’s NIC card.

Connect the equipment to a 36–60 VDC source that is electri-
cally isolated from the AC source. The 36–60 VDC source is to
be reliably connected to earth.

Pin No.

Signal

Direction

Signal

Name

1

Output

TX+

2

Output

TX-

3

Input

RX+

4

5

6

Input

RX-

7

8

CAUTION

Advertising
This manual is related to the following products: