7.1. Main Unit

7.1.1. Vertical Airflow Direction Vane.

Airflow direction adjustment Up-and-Down.

• The vertical airflow direction vane may

be

positioned

to

deflect

the

air

upwards,downwards or straight on.

Use the air conditioner under the following conditions:
• Operating temperature range.

I

ndoor side

Outdoor side

D.B.T. W .B.T. D.B.T.

W .B.T.

Cooling Maximum Temperature

32°C

23°C

43°C

26°C

Minimum Temperature

21°C

15°C

21°C

15°C

Heating Maximum Temperature

27°C

----

21°C

15°C

Minimum Temperature

20°C

----

-5°C

-6°C

7.1.2. Ventilation Lever.

W hen the slide lever is in the:

• “OPEN”position,the ventilation door is

opened to allow air,smoke and odors to
be expelled from the room.

• “CLOSE”position,the ventilation door is

closed and the air inside the room is
circulated and conditioned.

D.B.T.: Dry Bulb Temperature

W .B.T.: W et Bulb Temperature

Note: Humidity may exceed 90% .
− Continuous operation at humidity may create

condensation and result in water drops on the intake
and outlet vanes

7 Operating I

nstructions

7.1.3. Main Control Knob

7.1.4. Operation Conditions.