Adjustment range after lens position (optical shift)

Do not move the lens beyond the bounds of the shift range as this may cause a change in the focus. This

limitation is to protect the parts of the projector.

Using the standard projection position as the reference, the optical axis shift function makes it possible to adjust

the projection position in the ranges shown in the figures below.

PT-DZ570E

PT-DW530E

PT-DX500E

0.1 H

0.46 V

Projected screen

height, V

Projected screen width, H

0.1 H

0.6 V

Standard

projection position

0.65 V

0.1 H

Projected screen

height, V

Projected screen width, H

0.1 H

0.7 V

Standard

projection position

0.1 H

0.47 V

Projected screen

height, V

Projected screen width, H

0.1 H

0.6 V

Standard

projection position