Table 8. alarm configuration options – Paradyne ACCULINK 3172 User Manual

Page 15

Advertising
background image

13

Table 8. Alarm Configuration Options

Option

Factory 1

Comments/Description

Alrm Msg:

Enab

Determines whether alarm messages are
routed to the ASCII terminal or printer attached
to the COM port.

Disab

SNMP Trap:

Enab

Sends SNMP traps.

Disab

Table 9. General SNMP Configuration Options (1 of 2)

Option

Factory

Comments/Description

System Name:

Edit

The SNMP system name for this device.

Clear

System Location:

Edit

The SNMP system location for this device.

Clear

System Contact:

Edit

The SNMP system contact name for this
device.

Clear

CommunityName1:

Edit

A community name that is allowed access to
this device. Defaults to

public.

Clear

Access 1:

Read

The type of access allowed for community
name 1.

R/W

CommunityName2:

Edit

A community name that is allowed access to
this device.

Clear

Access 2:

Read

The type of access allowed for community
name 2.

R/W

IP Adr:

Edit

The IP address needed to access the device.

Clear

NetMask:

Edit

The Subnet Mask needed to access the device.

Clear

Advertising
This manual is related to the following products: