Appendixes

P r N o .

P a r a m e t e r Range

F u n c t i o n

d e s c r i p t i o n

• You can set-up the output timing of the in-position signal (COIN: CN I/

F Pin 10), completing the travel of the motor (work), after the command
pulse entry.

• The in-position (positioning complete) signal (COIN) will be fed-out

when the position error counter pulses fall within a preset range

• You can set-up the output timing of the zero speed detection signal

(WARN: CN I/F pin 12). Unit in [r/min].

• To enable output, Set "1" by Pr09.
• The WARN signal will be fed-out when the motor speed becomes

lower than this setting.

6 0

6 1

In-position

r a n g e

Zero speed

0 ~

32767

[10]

0 ~

10000

[50]

Decide the value of this parameter basing on
the resolution of the en-corder, like the figure
to the right.

< N o t e s >

1 . If you set-up too small value to Pr60, time to feed-out COIN signal gets longer, or

may causes a chattering.

2 . The value of this parameter does not affect the accuracy in positioning.

Pr61 affects both CW and CCW directions
regardless of the actual rotating direction.

COIN

10000 pulses
(for 1 revolution)

On

Pr60

Pr60

Speed

CW

WARN

ON

Pr61

Pr61

CCW

S e q u e n c e s