Appendixes

P r N o .

P a r a m e t e r Range

F u n c t i o n

d e s c r i p t i o n

6 6

6 8

6 9

DB inhibition at
overtravel limit

S e q u e n c e
at alarm

S e q u e n c e
at servo-off

0 ~ 1

0 ~ 3

0 ~

[ 0 ]

During deceleration

D B

Free run

D B

Free run

After stop

D B

D B

Free run

Free run

Operating conditions

Position

error counter

Cleared

You can set-up the conditions for decelerating the motor
after the over-travel limit input (CCWL: CNI/F Pin 9 or CWL:
CN I/F Pin 8) is made active.

Defines the conditions for decelerating the motor and keeping
t h e m o t o r s t o p p e d a f t e r o n e o f t h e a m p l i f i e r ' s p r o t e c t i v e
functions (alarms) is activated.

(DB: Dynamic brake activiated)

See also "Timing chart for alarms" in Appendix 11.

Defines the following processes after Servo-OFF (SER-ON signal:
CN I/F Pin 2).
1) Operating conditions during deceleration and after stop
2) Process for clearing the position error counter

For the relations among Pr69 values, operating conditions and process
for clearing the position error counter, see App.8ÅgDynamic brakeÅh.

See also "Timing chart for Servo-ON/OFF during the halt of motor"
in Appendix 12.

Motor operation from deceleration to and after stop

With the dynamic brake (DB) activiated the motor is stopped. After stop,

the dynamic brake is released.

Without dynamic brake the motor stops.

After stop, the motor remains free.