Preparations and adjustments – Panasonic MDDDT5540 User Manual

Page 29

Advertising
background image

- 29 -

The function differs depending on the control mode.

The function differs depending on the control mode.

G A I N /

ZEROSPD

D I V /

INTSPD1

Gain

s w i t c h i n g /

Speed zero

c l a m p

C o m m a n d

pulse scaler

s w i t c h /

Internal

c o m m a n d

v e l o c i t y

selection 1

5

6

S i g n a l

P i n

S y m b o l

F u n c t i o n

I / F

No.

c i r c u i t

Pr06 value

0

1 [Default]

M e a n i n g

ZEROSPD is disabled.

ZEROSPD is enabled

• The functions depend on the value of Pr30.

• Gain switching input results. Input for switching PI/P

operation and No. 1/No. 2 gains.

• For No.2 Gain change Funcution, see Protective Adjustments on page 57.
• Speed zero clamp input results. With COM- open, the

velocity command is considered zero.

• This input can be made disabled using Pr06.
• Default: Contact is set. With COM- open, the velocity

command is considered zero.

Preparations

and

Adjustments

SI

page 33

SI

page 33

At Pr31 value of 2

Position

control

Internal
velocity
c o n t r o l

F u n c t i o n

Speed loop:PI(ProportionalÅEIntegration) operation

Speed loop: P (Proportion) operation

#1 gain selection (Pr10, 11, 12, 13, 14)

#2 gain selection (Pr 18, 19, 1A, 1B, 1C)

Connection

to COM-

Open

Close

Open

Close

P r 3 0

value

0

(Default)

1

Position

control

Internal

velocity

c o n t r o l

• This is the input to switch command pulse scaler.

• With COM- closed, the numerator of the command scaler is changed

from the value stored in Pr46 (Numerator of 1st Command Scaler) to

the value stored in Pr47 (Numerator of 2nd Command Scaler).

<Note>

Don't enter command pulses 10 ms after or before switching.

• The internal velocity selection 1 (input) is valid. 4 kinds of velocity

settings are available by the combination with CL/INTSPD2 input.

• See control mode setting Pr02 (APP. 16).