Parameter Setting

Parameters for Defining the Real Time Auto Gain Tuning

Parameters for Adjustments (for 2nd Gain)

Parameter No.

Parameter description

Range

Default

Unit

(Pr**)

2nd gain action set-up

Position control switching mode

Position control switching delay time

Position control switching level

Position control swiching hysteresis

Position loop gain switching time

(Not available)

(Not available)

(Internal use)

0 ~ 1

0 ~ 8

0 ~ 10000

0 ~ 10000

0 ~ 10000

0 ~ 10000

-----

-----

-----

0

0

0

0

0

0

0

0

0

-----

-----

166µs

-----

-----

(1 + Setting value)

x166µs

-----

-----

-----

Ес

3 0

Ес

3 1

Ес

3 2

Ес

3 3

Ес

3 4

Ес

3 5

Ес

3 6

3 7 ~ 3 9

3 E ~ 3 F

Parameter No.

Parameter description

Range

Default

Unit

(Pr**)

Inertia ratio

Real time auto tuning set-up

Machine stiffness at auto tuning

(Not available)

(Internal use)

0 ~ 10000

0 ~ 3

0 ~ 9

-----

-----

1 0 0

0

2

1 0 0

0

%

-----

-----

-----

-----

Ес

2 0

Ес

2 1

Ес

2 2

Ес

2 3

2 4 ~ 2 F