4. Before Returning This Product to the User

Before returning this product to the user, always perform the following safety checks:

(1) Inspect all wiring to be sure no wires are pinched between the chassis or any metal parts.
(2) Inspect all protective devices for proper installation, including non-metallic controls, insulation materials, cabinet

backs, compartment covers, and shields.

(3) Verify that no shock hazard exists on any part of the chassis, especially any metal components including cable

connection points, chassis hardware, or antennas (if equipped). Use the following procedure:

a. Plug the AC cord directly into a 120 V AC outlet.
b. Create a test circuit consisting of a 1.5k ohm, 10

watt resistor paralleled by a 0.15 µF capacitor.

c. Using an AC voltmeter (sensitivity of 5000 ohm per

volt or higher), measure the voltage drop across

the test circuit between all exposed metallic parts
and a known earth ground. Measurement points

include antenna, metal cabinet parts, screw heads,

and metal knobs or controls. Measurement points

can vary slightly even between revisions of the

same model, so always conduct a thorough review

of the chassis to locate metal points that a user
may touch.

d. Any voltage reading of 0.375 Vrms AC (0.25

mArms) or higher indicates a potential shock

hazard. THIS CONDITION MUST BE

CORRECTED BEFORE RETURNING THE
PRODUCT TO THE USER!

e. Repeat the above checks with the AC polarity

reversed. A non-polarized adapter is required to

reverse the polarity; DO NOT LEAVE THIS

ADAPTER WITH THE USER! Under normal

operation the product must use the proper polarity.