background image

ActivMedia Robotics Operating System

With AROS versions 1.3 and later, many of the controller’s operating parameters return to

their FLASH-based default values upon disconnection with the client.

18

For example, if

the FLASH default for the maximum velocity is 1000 millimeters per second, and your

client uses the SETV command #6 to reset the maximum velocity to 500 millimeters per

second, the maximum velocity automatically will revert back to 1000 after your client
disconnects and then reconnects for a subsequent session.

M

OTION

C

OMMANDS

The AROS motor-control servers accept several different client-motion commands of two

mutually exclusive types: either independent-wheel or platform translational/rotational
movements. The AROS servers automatically abandon any translational or rotational

setpoints and switch to independent wheel-velocity controls when your client issues the
independent-wheel VEL2 command #32, and vice versa.

Note that once connected, ActivMedia robots’ motors are disabled, regardless of their

state when last connected. Accordingly, you must either enable the motors manually
(white MOTORS button on the User Control Panel) or send the motors ENABLE client

command #4 with the argument value of one.

19

Monitor the status of the motors with bit

0 of the Flags integer in the standard SIP.

When in independent-wheel velocity mode (VEL2), the robot’s motion-control servers do

their best to maintain precise wheel velocities. In practice, wheel slippage and uneven

terrain will cause the robot to change heading, which your client must detect and
compensate. When in translational/rotational (TR) motion control mode

(recommended), your robot’s servers work to maintain both platform speed and

heading.

Table 6. AROS motion commands

Rotation

HEAD

(#12)

Turn to absolute heading at SETRV max velocity

DHEAD

(#13),

DCHEAD

(#22)

Turn to heading relative to control point at SETRV max velocity

ROTATE

(#9)

Rotate at SETRV velocity

Translation

VEL

(#11)

Translate forward/reverse at prescribed velocity (SETV maximum)

MOVE

(#8) Translate

distance

at SETV max velocity

Independent Wheel

VEL

2 (#32)

Set velocity for each side of robot (SETV maximum)

18

With earlier versions, the changes persisted between sessions, and reverted to the FLASH defaults only after

the controller was reset.

19

Alternatively, disable the motors with the ENABLE command argument of zero.