Gain control setting [agc, White balance setting [white bal – Panasonic WV-CP504 User Manual

Page 12

Advertising
background image

12

When the SUPER-D5 function is set to "OFF": OFF (1/60) (default), 1/100, 1/250, 1/500, 1/1 000, 1/2 000, 1/4 000, and

1/10 000

When the SUPER-D5 function is set to "ON" or "ON(i-VMD)": OFF (1/60) (default), 1/100

Note:

• When "ALC/ELC" is set to "ELC" or "ALC+" (+ page 9), "---" appears and the electronic shutter function cannot be activated.
• If the controller, WV-CU254 or WV-CU204 is used, SW LED and the status of "SHUTTER" are not correctly displayed.

4. Gain control setting [AGC]

Select a gain control setting from the following.
ON (HIGH) (default)/ON (MID)/ON (LOW): Automatically increases the gain to make the screen brighter when the illuminance of

the subject becomes darker.

HIGH, MID and LOW indicate the gain level.
OFF: Does not increase the gain.

Note:

• When "SENS UP" is set to the AUTO mode, “AGC” cannot be set to “OFF”.

5. Electronic sensitivity enhancement setting [SENS UP]

Use of the electronic sensitivity enhancement function increases the quantity of light stored on the CCD, and accordingly the
image becomes brighter. The magnification is unchanged for selection of FIX, and the magnification is changeable in accor-
dance with the illuminance of a photographic subject for selection of AUTO.
The magnification of the electronic sensitivity is selectable from the following. The setting of the SUPER-D5 function restricts the
available setting range.
When the SUPER-D5 function is set to "OFF": OFF (default)/X2 AUTO/X4 AUTO/X6 AUTO/X10 AUTO/X16 AUTO/X32 AUTO/

OFF/X2 FIX/X4 FIX/X6 FIX/X10 FIX/X16 FIX/X32 FIX

When the SUPER-D5 function is set to "ON" or "ON (i-VMD)": OFF (default)/X2 AUTO/X4 AUTO/X6 AUTO/X10 AUTO/X16

AUTO/X32 AUTO

Note:

• When "ALC/ELC" is set to "ELC" or "ALC+" (+ page 9), or "SHUTTER" is set to "1/100" (+ page 11), only the AUTO mode is

enabled.

• When "SHUTTER" is set to "OFF" or other than "1/100", the electronic sensitivity enhancement setting cannot be performed.

"---" appears and "OFF" is selected.

• It is impossible to select "AUTO" for "SENS UP" and "1/100" for "SHUTTER" using the following system controller. Use the

operation buttons for the setting.

WV-CU300, WV-CU354, WV-CU204, WV-CU254
• When the magnification of "SENS UP" is increased, the screen becomes coarser, more whitish, or more flawed. However, this

phenomenon is normal.

• If the controller, WV-CU254 or WV-CU204 is used, SW LED and the status of "SENS UP" are not correctly displayed.

6. White balance setting [WHITE BAL]

The white balance adjustment is selectable from the following.
ATW1 (default): Activates the automatic color temperature tracking mode. The camera continuously measures the color tem-

perature of the light source and automatically adjusts the white balance. The adjustment of the color temperature ranges
from approx. 2 700 K to 6 000 K.

Advertising