Alarm input/output terminal setting [alarm in/out, Configure the alarm input terminal settings – Panasonic WV-CP504 User Manual

Page 23

Advertising
background image

23

Step 1

Set "SYNC" to "LL" and press the setting button.

→ The "SYNC" screen appears.

Step 2

Connect the video output signal and external synchronizing input signal of the camera to a 2-input oscilloscope, and move the
cursor to "COARSE".

Step 3

Adjust the oscilloscope to the vertical rate, and extend the vertical synchronizing part of the oscilloscope.
Move the cursor horizontally with use of the right or left button to roughly adjust the vertical phase.
The phase can be adjusted in 16 steps by 22.5 degrees.
1 (1--16) : 0 °/2 (1--16) : 22.5 °/· · ·/16 (1--16) : 337.5

Step 4

Move the cursor to "FINE", and fine adjust vertical phases.

11. Alarm input/output terminal setting [ALARM IN/OUT]

Configure the settings relating to the alarm input/output terminal as follows.

Configure the alarm input terminal settings

Select the operation of the alarm input terminal. Follow the procedure below.

Step 1

Move the cursor to "ALARM IN/OUT" and press the setting button.
→ The "ALARM IN/OUT" screen appears.

Step 2

Move the cursor to "ALARM IN" and select the alarm input terminal operation from the following.
OFF (default): No terminal input is accepted.
ALARM: Activates the alarm action when the terminal input is active for more than 100 ms.
VMD PERMIT: Activates the intelligent VMD function when the terminal input is active. It is necessary to set actions to be taken

in the "i-VMD" section in advance. (+ Page 16)

BW: Automatically activates the black and white mode when the terminal input is active.
SCENE2: Operates the camera with the settings of "SCENE2" when the terminal input is active.
When no terminal input is received, the camera will work with the settings of "SCENE1".

**SYSTEM SETUP**

SYNC INT

ALARM IN/OUT

PRIVACY ZONE OFF

STABILIZER OFF

EL-ZOOM OFF

RET TOP END

"ALARM IN/OUT" screen

"SYSTEM SETUP" screen

**ALARM IN/OUT**
ALARM IN OFF

ALARM OUT OFF

RET TOP END

Advertising
This manual is related to the following products: