Main menu screen 2 of 4 (sub menus), Vtr function screen – Panasonic AJ-D610WBp User Manual

Page 128

Advertising
background image

– 128 –

Item

HUMID OPE

26P CONTROL

REC START

TC MODE

UB MODE

PAUSE TIMER

BATTERY SEL

Variable

range

ON
OFF

OFF
BOTH
ON

ALL

NORMAL

DF
NDF

USER
DATE
TIME
EXT

10
20
30
60

NiCd12
NiCd13
NiCd14

IDXL-40

L-60
L-90

ANTON-

D

IDX-D

Remarks

This selects the VTR operation when
condensation has formed.
ON: Operation continues as usual.
OFF: All operations are disabled
except for the POWER switch and
EJECT button.

This selects 26P remote control.
OFF: Unit only (no 26P control).
BOTH: Unit and 26P remote control
(tally LED displays unit’s REC status).
ON: 26P remote control only (tally
LED displays 26P VTR’s REC status).

This selects in what VTR mode REC is
to be acknowledged when the VTR is
started or stopped.
ALL: REC is acknowledged in any
VTR mode.
NORMAL: REC is acknowledged only
in the STOP (power save) mode and
REC PAUSE mode.

This sets DF or NDF for the time code.
DF: Drop frame mode
NDF: Non-drop frame mode

This selects how LTC UB is to be
used.
USER: User setting (fixed setting)
DATE: For year/month/day/hour real-
time operations.
TIME: For hour/minute/second real-
time operations.
EXT: The UBG value is slave-locked
when an external TC signal has been
input. (The user setting is used when
there is no external input.)

This selects the time for which the
REC/PAUSE status is to be
maintained.
10/20/30/60: Status is to be held for
10, 20, 30 or 60 minutes.

This selects the battery type.
NiCd12:

When a 12V NiCd battery is used

NiCd13:

When a 13V NiCd battery is used

NiCd14:

When a 14V NiCd battery is used

IDXL-40: When the L-40 battery made
by IDX is used
L-60/L-90: When a battery made by
Sony is used
ANTON-D: When a battery made by
Anton Bauer is used
IDX-D: When a battery made by IDX
is used digitally

VF

display

ENG

ENG

ENG

ENG

ENG

ENG

ENG

MAIN Menu Screen 2 of 4 (SUB menus)

VTR FUNCTION screen

The VTR’s functions are set on this screen.

{

V T R

F U N C T I ON

H UM I D O P E

:
:
:
:
:
:
:
:
:
:

O F F
O F F

O F F
O F F

2 6 P CON T RO L

R E C S T A R T

NORMA L

T C MOD E

MOD E

D F

U B

U S E R

P A U S E

T I ME R

3 0

B A T T E R Y

S E L

N i C d 1 2

T CG
T CG

V F

D I S P

S E T

HO L D

F I R S T

R E C

T C R E G E N

¢|

|

Notes

{

Á

Set SW201 on the CAM ENC
board and SW1 (26PIN) on the
CAM SYNC board to ON when the
26P remote control function is to
be used.

Á

Change the time on the TIME/
DATE menu screen when the
REAL setting is to be used for the
UB MODE item.

The underlining in the variable range
column indicates the setting in the
preset mode.

Advertising