8.8. Horizontal Airflow Direction Control

The horizontal airflow direction louvers can be adjusted manually by hand.

8.9. Powerful Operation

The Powerful operation is to achieve the setting temperature quickly.

When Powerful operation is set, the setting temperature will be automatically decreased 5.4°F internally against the present
setting temperature (Lower temperature limit: 60.8°F).

This operation automatically will be running under SHi Fan Speed (Cooling), Lo- Fan Speed (Soft Dry).

Vertical Airflow Direction:-
- In “Manual” setting, the vane will automatically shift down 10° lower than previous.
- In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.

Powerful Mode will operate for 15 minutes only and operation will shift back to previous setting mode.

Powerful operation stops when:-
- Powerful mode button is pressed again.
- Stopped by OFF/ON operation button.
- Timer OFF activates.
- Quiet mode button is pressed.
- Operation mode button is changed.
- Economy mode button is pressed.