8.10. Quiet Operation

(For Cooling Operation or cooling region of Soft Dry Operation)

The Quiet operation is to provide quiet/cooling operation condition compare to normal operation.

Once the Quiet Mode is set at the remote control, the Quiet Mode LED illuminated. The sound level will reduce around 2 dB
for Lo fan speed or 3 dB for Hi/Me fan speed against the present operation sound level.

Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1hr 30 min (1hr QLo, 30 min QLo +
80 rpm). After that, it goes back to Lo cool (However Quiet LED remains on).

Manual Airflow Direction:-

RPM control during Lo cool

RPM control during Hi cool

Auto Airflow Direction:-

Quiet operation stops when:-

Quiet button is pressed again.

Stopped by OFF/ON operation button.

Timer OFF activates.

Powerful button is pressed.

Economy button is pressed.

Operation mode button is changed.