D.3.16 discrete 2 of 5, D.3.17 telepen – PYLE Audio IKON RUGGED 7505-BT User Manual

Page 380

Advertising
background image

D-32

Ikôn Rugged PDA (Windows Mobile 6.1) User Manual

Appendix D: Bar Codes Settings
Discrete 2 of 5

D.3.16 Discrete 2 of 5

Enabled
Set this parameter to on to enable “Discrete 2 of 5”.

Standard 2 of 5 Format
This parameter allows you to choose a standard format – either Identic on (6 start/stop bars)
or Computer Identics (4 start/stop bars)
.

Check Digit Verification
The available options for this parameter are Disabled and MOD 10 Check. “Check Digit
Verification” uses the specified algorithm of the option you've chosen to ensure the integrity
of the symbol data before transmitting. If the data does not contain that algorithm, the data is
not transmitted.

Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.

Set Length L1, Set Length L2, And Set Length L3
Lengths for “Discrete 2 of 5” can be set from 0 to 255. The length of a code refers to the
number of characters (i.e., human readable characters), including check digit(s).
Double-tapping on these parameters displays dialog boxes where you can define the code
length that will be recognized by your scanner.

Length Mode
You can chose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length.

Length Restriction
Refer to “Length Restriction” on page D-8 for details.

Add/Remove Data
Refer to “Add/Remove Data” on page D-9 for details.

D.3.17 Telepen

Enabled
Set this parameter to on to enable “Telepen”.

Advertising
This manual is related to the following products: