Cbaud, baud rate regulation, Cbaud, baud rate regulation -132, Cbaud parameters -132 – PIONEERPOS AT Commands G24-LC User Manual

Page 196

Advertising
background image

Hardware Information

3-132

G24-L AT Commands Reference Manual

April 15, 2008

+CBAUD, Baud Rate Regulation

This command sets the baud rate. The baud rate of the G24-L is changed/set to the request value
<rate> written in the command.

Specifying a value of 9 or 0 disables the function and allows operation only at rates automatically
detectable by the G24-L. The specified rate takes effect following the issuing of any result
code(s) associated with the current command line.

The UART is configured according to the request, or to the specific constant baud rate or auto
baud rate after output "OK" response to the terminal. For example, AT+CBAUD=8 is equivalent
to AT+CBAUD=57600. Using AT+CBAUD with the <rate> value other than 9 or 0 disables the
auto baud rate detection feature.

The following table shows the +CBAUD parameters.

Example

AT+CBAUD=57600

or

AT+CBAUD=8

//These commands have the same effect

OK

Command Type

Syntax

Response/Action

Set

AT+CBAUD=<n>

AT+CBAUD=<rate>

OK

or:

ERROR

Read

AT+CBAUD?

+CBAUD: <rate>

Test

AT+CBAUD=?

+CBAUD: (list of supported <n>s, list of

supported <rate>s)

Table 3-84: +CBAUD Parameters

<Parameter>

Description

<n> <rate>

0

Auto baud rate

1

600

2

1200

3

2400

4

4800

5

9600

6

19200

7

38400

8

57600

9

Auto baud rate

10

115200

11

300

12

230400

13

460800

The default value is 9.

Advertising