Chapter 3: AT Commands Reference

April 15, 2008

G24-L AT Commands Reference Manual

3-183

+CPWD, Change Password

This command sets a new password for the facility lock. The password can only be changed once
the required facility is enabled by the +CLCK command. (Refer to

“+CLCK, Facility Lock” on

page 3-184

).

A password can be changed only if the provided password <oldpwd> has been verified. The
entered password <newpwd> must also comply to the password rules. The facility value <fac> is
not case-sensitive. In the password value, letters are not allowed.

The following table shows the +CPWD parameters.

Command

Type

Syntax

Response/Action

Remarks

Set

AT+CPWD=<fac>,

<oldpwd>,
<newpwd>

OK

or:

+CME ERROR: <err>

The Set command sets a new password for
the facility lock function, defined by the
+CLCK command. (Refer to

“+CLCK,

Facility Lock” on page 3-184

).

Read

AT+CPWD?

+CME ERROR: <err>

Test

AT+CPWD=?

+CPWD:list of

supported
(<fac>,<pwdlength>)s

OK

or:

+CME ERROR: <err>

The Test command returns a list of pairs
which represent the available facilities, and
the maximum length of their passwords.

Table 3-123: +CPWD Parameters

<Parameter>

Description

<fac>

List of supported facilities. All the facility messages, except for SC and P2, are sent to
the network. (The facilities are not case-sensitive.)
SC

SIM (lock SIM card)

The SIM requests the password during G24-L power-up and when this command is
issued.
AO

BAOC (Bar All Outgoing Calls)

OI

BOIC (Bar Outgoing International Calls)

OX

BOIC-exHC (Bar Outgoing International Calls except to Home Country)

AI

BAIC (Bar All Incoming Calls)

IR

BIC-Roam (Bar Incoming Calls when Roaming outside the home country)

AB

All Barring services (applicable only for <mode>=0)

AG

All outGoing barring services (applicable only for <mode>=0)

AC

All inComing barring services (applicable only for <mode>=0)

P2

SIM PIN2 (

Refer to “+CLCK, Facility Lock”, page 3-184

)

<oldpwd>

String type, 4-8 character password specified for the facility from the G24-L user
interface.

<newpwd>

String type, 4-8 character new password specified by the user.

<pwdlength>

Maximum length of the facility password. Integer type.

Advertising