S102 parameters -204 – PIONEERPOS AT Commands G24-LC User Manual

Page 268

Advertising
background image

Modem Configuration and Profile

3-204

G24-L AT Commands Reference Manual

April 15, 2008

The following table shows the S102 parameters.

Example

ATS102? <enter>

030

OK

ATS102=100 <enter>

OK

ATS102? <enter>

100

OK

(This means if there is data for transmission to the terminal, the G24-L drops the Wakeup Out
line, waits 100 ms. and then sends data to the terminal.)

S100, Set Minimum Time for Terminal to Fall into Sleep Mode

ATS100 is a terminal minimum time limit for entering sleep mode.

In order to limit the number of interrupts on the DTE side and reduce data sending delay time on
our side, G24-L sends wakeup-out pulse when the interval between one burst of sent/received
data to the other is bigger than specified in ATS100.

Command Type

Syntax

Response/Action

Remarks

Set

ATS102 = <value>

OK

The Set command sets the delay before
sending data to the terminal, and
defines a period between sending the
wakeup signal and sending data to the
terminal.

Read

ATS102? <value>

OK

The Read command returns the current
value.

Table 3-136: S102 Parameters

<Parameter>

Description

<value>

0 <= value <= 255
The default value is 30 ms.

Command Type

Syntax

Response/Action

Remarks

Set

ATS100=<delta>

OK

Or

+CME ERROR: <err>

The set command sets the terminal
minimum time limit for entering sleep
mode.

Read

ATS100?

<delta>

OK

The Read command returns the current
ATS100 value.