Warning indications

47

Error codes

When an error occurs, the three-digit display will indicate the error code.

Display

Error name

Error description

E00

Interlock emergency stop

The interlock contact was opened during
irradiation.

CH1-4 E10

Connection error

The LED head was disconnected.

CH1-4 E20

LED break error

A circuit break was detected in the LED
head during irradiation.

CH1-4 E30

LED short-circuit error

A short-circuit of the LED head
was detected during irradiation.

CH1-4 E40

LED temperature error

The LED head temperature reached an
abnormal level.

CH1-4 E50

LED time error

The cumulative time of the LED has
reached the set replacement time.

CH1-4 E60

STEP1 calibration error

CH1-4 E61

STEP2 calibration error

CH1-4 E62

STEP3 calibration error

CH1-4 E63

STEP4 calibration error

CH1-4 E64

STEP5 calibration error

CH1-4 E65

STEP6 calibration error

CH1-4 E66

STEP7 calibration error

CH1-4 E67

STEP8 calibration error

CH1-4 E68

STEP9 calibration error

CH1-4 E69

STEP10 calibration error

The set UV intensity was not reached.