VIX AE SERVO DRIVE USER GUIDE

M

Mode

Syntax

Units

Range of ‘n’

Default

See also

aMn

-

see below

-

-

Description

The mode command sets up the mode of operation of the drive.

The values of n are:

P – base servo position mode (step and direction input)
T – base servo torque mode (analogue torque input)
V – base servo velocity mode (analogue velocity input)

Properties

Immediate, saved by SV

Example 1

The code below sets up for torque demand.

3MT

;mode torque

To check the current mode, type...................................... 3M
The response will be ........................................................ *MT

Note

The drive must be de-energised for the M command to be executed. If the
command is issued whilst the drive is energised, an error message will be
generated and the command will be ignored.

When re-energising the drive will respond immediately to the new
demand.

See GAINS command for gain parameters relevant to the particular mode.