Setupfb setup motor feedback, Setupfb, Setup motor feedback – Parker Products ViX250AE User Manual

Page 105

Advertising
background image

98

VIX AE SERVO DRIVE USER GUIDE

SETUPFB

SETUP motor FeedBack

Syntax

Units

Range of ‘n’

Default

See also

aSETUPFB

-

-

-

K

Description

For a correctly wired Parker motor, this command is not required.
However, when commissioning problems occur with a motor/drive system,
the SETUPFB command can be used to troubleshoot motor wiring problems
in encoder and resolver units and to temporarily compensate for these
errors.

The command reports wiring errors to the user:

Correct these errors in hardware before shipping any system.

If the command cannot correct an error it will display a message indicating
the nature of the problem, followed by a FAIL message.

CAUTION

DO NOT COUPLE ANY MACHINERY TO THE MOTOR SHAFT WHILE
RUNNING THIS COMMAND AS SHAFT MOVEMENT WILL OCCUR.

Correct your wiring, as this will prevent future problems if you replace your
motor or drive, since the software correction cannot be uploaded from a
drive. Note, if you do use SETUPFB to permanently correct errors in non-
standard motor/drive systems, you will need to run the MOTOR command
followed by SETUPFB on every system.

Properties

Immediate, saved by SV

Example

1SETUPFB

;commission a new motor attached to the drive

Note

You can abort this command using the KILL command. Under these
circumstances, energising cannot take place until SETUPFB is correctly
executed .