Status status of drive, Status, Status of drive – Parker Products ViX250AE User Manual

Page 106: Command reference 99

Advertising
background image

6. COMMAND REFERENCE

99

STATUS

STATUS of Drive

Syntax

Units

Range of ‘n’

Default

See also

aSTATUS

-

-

-

Description

Use this command to check the state of a drive. It is intended for set-up
purposes rather than for use when a program is running.

Properties

Immediate or buffered, can’t be used in a labelled block, not saved by SV

Example

1STATUS

;checking the configuration and state of a drive

1STATUS
*ViX500AE-Servo Copyright 2002 Parker-Hannifin
*Firmware: REV 1.4 Dec 03 2002 17:11:23 Map No: 124
*Serial number: ..541935.00.1.4. -ViX500xx
*Control card revision 2

Servo drive

*Power card revision 3

Servo power stage E500

*Motor type undefined
*
*FPGA_ID (read)......... 1070

FPGA_ID (file)....... 1070

*
*MOTOR TYPE ............ 0

RESOLUTION .......... 4000

*CONT. STALL CURRENT ... 0.1 Amps

POLES ............... 8

*PEAK CURRENT (PC)...... 300 %

TRACKING LIMIT (TL).. 4000

*INDEX POSITION (IX).... 250
*
*MOTOR SUPPLY........... 81 V

AUX SUPPLY........... 5.1 V

*I/O SUPPLY............. 23 V

I/O CONFIGURATION.... 256

*INTERNAL TEMPERATURE... 28 C

HEATSINK TEMPERATURE. 25 C

*
*INCREMENTAL INDEXING (MI)
*VELOCITY (V)........... 1.00

DISTANCE (D)......... 4096

*ACCELERATION (AA)...... 10.0

DECELERATION (AD).... 10.0

*CURRENT POSITION (PA).. -471

ERROR (PE)........... 0

*
*AXIS: READY
*DRIVE FAULTS (DF): 0000_0000_0000_0000_0000_0000_0000_0000
*DRIVE STATUS (ST): 0000_0000_0000_0000_0001_0000_0000_0000
*USER FAULTS (UF): 0000_0000_0000_0000_0000_0000_0000_0000

Note: Motor type has not been defined.