6. COMMAND REFERENCE

101

W

Write system variable

Syntax

aW(system_variable,value)

Description

The W command allows you to set a specified system variable to a
particular value.
Refer to the table of system variables for more information.

Properties

Immediate not saved by SV

Example

Set system variable TL (Tracking Limit) to 4000
Report the current value of system variable TL
The controller responds with......................................

2W(TL,4000)
2R(TL)
*4000

Note

The drive will need to be de-energised before certain system variables can
be written to.

See also R command.

See table of allowable variables for individual parameter details.

Z

Reset

Syntax

Units

Range of ‘n’

Default

See also

aZ

-

-

-

SV

Description

The Z command resets the drive. This is similar to power cycling the drive.

Wait 1-2 seconds before sending any other command following a Z.

Following the issue of the Z command, any configuration which has been
made but not saved, with the SV command, will be lost.

Properties

Immediate, not saved by SV

Example

To reset all drives, type....................................................

0Z