Complete led diagnostics – Parker Products ViX250AE User Manual

Page 117

Advertising
background image

110 VIX AE SERVO DRIVE USER GUIDE

Complete LED Diagnostics

An EASI-V version of this table is available for quick on-line viewing.

LED

Colour(s)

Flash rate

Functional description

HV

green

none

motor supply OK

HV

orange

none

motor supply under voltage (<16V)

HV

red

none

motor supply over voltage (>96V)

HV

off

-

no motor supply

ST

green

none

drive OK and motor is energised

ST

orange

none

drive OK but motor is de-energised

ST

red

none

drive fault (see DF report for more information)

ST

red/green

1 second

I

2

t duty cycle too high. Bit 16 of ST system

variable set to 1.

ST

red/green

0.25 second

communications receive buffer over-flow. Only
a power-cycle clears this condition.

ST

red/off

0.5 second

only on power-up following a flash upgrade.
Indicates bad truncated FPGA file.

ST

red/off

1 second

only on power-up following a flash upgrade.
Indicates a CRC error.

ST

off

-

no logic supply. All other LEDs will also be off.

FB

green

none

fieldbus communications OK. Operational state.

FB

green

1 second

fieldbus communications OK. Pre-operational
state.

FB

red

none

fieldbus communications fault

FB

off

-

no fieldbus option

Table 7-1. Status Bits Description (continued)

Advertising