8. HARDWARE REFERENCE

113

8. Hardware Reference

Drive Functional

Specification – ViX250AE, ViX500AE

Parameter

Value

Maximum output current

Maximum continuous power drawn from the
supply

ViX500: 5A RMS continuous
15A RMS peak (2 seconds max.)*
ViX250: 2.5A RMS continuous
7.5A RMS peak (2 seconds max.)*

6.3A at 80V (500VA)

Motor HV supply input
(No reverse polarity protection, HV
reversal WILL damage the drive)

ViX500: 48 – 80V DC +5% -15%
ViX250: 24 – 80V DC +5% -15%

Minimum PSU capacitance

ViX500: 6,600

µ

F

ViX250: 3,300

µ

F

Controller supply input

24V DC +10% to –15%

Protection

Short circuit (phase-to-phase, phase-to-
ground)
Motor HV over and under voltage trip
(HV over voltage 98V nominal)
Drive over-temperature
Motor over-temperature (motor dependent)
24V reverse polarity
Commutation encoder fault
Resolver fault

Temperature protection (motor protection
depends upon the type used) see Note 1.

I

2

t circuit protects motor and drive from

excessive dissipation

Motor current limit

Selectable by software

Motor inductance range

0.5 to 10 mH For lower inductance motors
consult Digiplan

Fault output

NPN open-collector output, normally low,
active high

Enable input

24V input with pull-up resistor (can be
software set to be active high or active low)

LED status indicators (tri-colour)

HV/feedback fault
Drive fault
Comms. status

* 2 sec rotating 0.4 sec stationary – see Plots of I

2

t Against Drive Current

Table 8-1. Functional Specification

Note 1 – See Motor Overtemperature Sensor in Electrical Installation section.