10

VIX AE SERVO DRIVE USER GUIDE

Power Supply Connections

Power drives from a DC supply derived from an isolating transformer or a DC power supply
(See Power Supply Options later in this section).

Note: Pin 10 is at the top of the connector X1 and pin 1 at the bottom.

X1

+HV

-HV

PE

+24V

9

8

7

6

5

4

3

2

0V (GND 24v DC)

MOTOR
CONNECTIONS

10

1

Power & motor
10-way
connector

Figure 3-1. X1 Power Connections

WARNING – Possible drive damage

If you use Parker XL Series stepper drives do not attempt to use any power wiring

harness taken from an XL drive. Although the same mating connector is used for
both an XL and a ViX, the ViX wiring is the reverse of the XL and the wrong wiring

connection will damage the drive.

Mating connector type is: Wieland type number 8213B/ . This connector is available in two
forms:

1. Part number 25.323.4053.0 (Parker part number 0405.811)
2. UL marked version with part number 25.323.1053.0