Reset to rs232 mode, Electrical installation 39 – Parker Products ViX250AE User Manual

Page 46

Advertising
background image

3. ELECTRICAL INSTALLATION 39

Reset to RS232 Mode

To reset the drive to RS232 mode and to return to factory settings, remove power from the
drive, connect X3 pin2 to GND and restore power.

CAUTION

This will erase ALL of your user settings and programs in volatile memory. The non-

volatile memory will not be overwritten until a save command is issued.

1

5

PC RS232 socket Interface

X3 Socket

Serial connector
plug

Serial connector
socket

Back of
mating plug

Back of
mating plug

Back of
mating socket

Back of
mating plug

6

9

Drive

GND

CONN.
SHELL

CONN.
SHELL

Rx

Tx

5

1

9

6

X3 Socket

5

1

9

6

1

14

25

13

4 Rx

5 Tx

3 GND

3 Tx

2 Rx

5 GND

X3

SERIAL

Terminal RS232 socket Interface

Terminal/PC

GND

Rx

Tx

4 Rx

5 Tx

3 GND

2 Tx

3 Rx

7 GND

X3

SERIAL

Figure 3-19. X3 D-type Connector RS232 Connections