X4 connector – Parker Products ViX250AE User Manual

Page 48

Advertising
background image

3. ELECTRICAL INSTALLATION 41

X4 Connector

Connector X4 gives access to the following encoder input and output signals and the
differential analogue inputs. Input and output connections are dependent upon the state of
system variables EO and EI.

Connector Type

Connector type is a high-density 15-way D-type socket.

Connector Pin Out

Connector Pin X4

Encoder I/O

1

ANA1+ (input)

2

ANA1- (input)

3

0V

4

/Z index out

5

Z index out

6

Fault (output)

11

Energise/* (input)

Energise

*See system variable ES

Table 3-12. X4 Encoder I/O Connections

Inputs Depending Upon the State of System Variable EI

Connector Pin

X4

EI=0

EI=1

EI=2

12

STEP+

CW+

A+

7

STEP-

CW-

A-

13

DIR+

CCW+

B+

8

DIR-

CCW-

B-

Outputs Depending Upon the State of System Variable EO

Connector Pin

X4

EO=0

EO=1

EO=2

14

STEP+

CW+

A+

9

STEP-

CW-

A-

15

DIR+

CCW+

B+

10

DIR-

CCW-

B-

Advertising