Fault output, Fault output drive circuit – Parker Products ViX250AE User Manual

Page 50

Advertising
background image

3. ELECTRICAL INSTALLATION 43

Figure 3-22 shows the input characteristic.

+10V

-10V

Commanded
velocity

Volts

Velocity
(rps)

Dead band

Figure 3-22. Analogue Differential Input Characteristic

Fault Output

The fault output is an independent NPN open-collector output, which is normally ‘low’ active
‘high’. The output ratings are +30V maximum in the OFF condition and 15mA maximum in
the ON condition. Figure 3-23 shows the output circuit.

Fault
Output

Drive
circuit

0V

Figure 3-23. Fault Output Circuit

Advertising
This manual is related to the following products: