48

VIX AE SERVO DRIVE USER GUIDE

Communication Daisy Chain

Drives can be ‘daisy-chained’ for RS232 operation as shown below. Using this arrangement
the drive connected to the controlling PC, via its front panel D-type connector, becomes axis
#1. To automatically assign addresses, connect all power, motor, feedback and
communication cables then power-up all the drives, see ‘#’ command for more details. At
the controlling PC, type the following commands:

#1

;cause the 1

st

drive to establish the daisy chain

in a 3-axis system the response will be #4
0SV

;save the address configuration

0Z

;reset

response should be a single check sum from axis 1
more than one check sum indicates a problem, possibly no save command

RS232 Input from PC

Final drive
terminates
the daisy chain

X6 rear

X7 front

X7 front & X6 rear

X7 Out
X6 In

Figure 3-27. RJ45 RS232 Daisy Chain Connections

Using the X6/X7 connections on the underside of the drive will allow the last drive in the
chain to detect that there are no more connections made to X7 which will close the daisy
chain loop back internally.