VIX AE SERVO DRIVE USER GUIDE

BRAKE

Brake configuration

Syntax

aBRAKEn(mode,RD,ED)

Description

n

is used to release a brake and to cancel any previously

selected automatic mode.

mode selects the way the brake is used

A

automatic holding brake mode

D

automatic dynamic brake mode

E

external input used for brake (AE variant only)

M

brake modes disabled (default)

RD is the time in milliseconds for the brake to release after the drive has
energised. Range is 0 to 5000 milliseconds (default 50ms).
ED is the time in milliseconds for the brake to engage before the drive de-
energises. Range is 0 to 5000 milliseconds (default 50ms).

Properties

Immediate, saved by SV

Note

This command configures the brake. Before you can execute a brake
command, you must send the drive a valid motor command where the
motor type has a brake fitted.

The brake input will only be active in mode E.

WARNING

In mode E, control of the motor brake is immediate with no

delays. You must ensure this form of direct control is safe and

appropriate for your application.