VIX AE SERVO DRIVE USER GUIDE

H

Change direction

Syntax

Units

Range of ‘n’

Default

See also

aHn

-

+ or -

+

STATUS

Description

The H command changes the direction of motion according to a positive
demand signal. A blank value following the H command will be ignored.

Properties

Immediate, saved by SV

Note

The drive must be de-energised for the H command to be executed. If
the command is issued whilst the drive is energised, an error message
will be generated and the command will be ignored.

Specifying H+ sets the direction to clockwise for a positive analogue input
voltage and H- produces counter clockwise rotation for a positive input
voltage.

The direction assigned to H can be reported using the STATUS
command.