6 scfg command – Polycom KIRK 14117800 User Manual

Page 195

Advertising
background image

Configuration of the Update Server 195

KIRK Wireless Server 600v3 Installation and Configuration Guide

determines whether the DECT radio code PCS04fd was already installed. If this is not the

case, the current DECT radio code is downloaded from the address 192.168.0.10/firm/

ccfp1200.bin, the UPDATE/BMC internal variable is overwritten with PCS04fd and,

finally, the device is reset as soon at it is not being actively used.

13.5.6 SCFG Command

mod cmd UP0 scfg <url> [<final-command> <save-serial> [ /force <hours> ]]

This will cause the device to upload its current configuration to <url>. This will be done

using an HTTP PUT command. <url> must be writable thus. Within <url>, some meta

character strings are replaced as follows:

Sequence

Replaces

Example

#F

kernel build number

08-12345

#B

boot code build number

401

#H

hardware build

102

#h

Device hardware number

P1200-03-0d-f0

#m

MAC address of the device

00-90-33-03-0d-f0

#d

Current date and time

20051010-170130

#bn

rolling backup index

3

#i

(one of) the local ip-address(es) 192.168.0.1

The rolling backup index loops over 0 .. n-1 for each backup.

Beginning with V7.00 the optional Parameters <final-command>, <save-serial> and /

force <hours> will be recognized.

<final-command> defines the command to be executed after successful completion of

scfg (typically no-op is used).

<save-serial> is compared to the UPDATE/SCFG variable. If it is not equal, the

command is started. If it is equal and /force is not specified the command is skipped,

otherwise /force is evaluated.

/force <hours> specifies the number of hours after which scfg is executed again even if

<save-serial> has not changed.

mod cmd UP0 scfg http://192.168.0.10/configs/saved/#h#b5.txt no-op WEEKLY /force 168

will save the device configuration once per week with a backlog of 5 weeks.