26 Introduction

14117800, Ed.2.6

2.2 Requirements for the KIRK Wireless Server 600v3 Solution

This section provides information about the environmental and electrical requirements

and software requirements for the KWS600v3 Solution.

2.2.1 KIRK Wireless Server 600v3

2.2.1.1 Environmental Requirements

The following is a list of recommendations for suitable installation conditions:
• Verify that the installation area is clean, dry, and protected from weather extremes.
• Verify that the floor of the installation area is finished with linoleum, vinyl, ceramic,

wooden flooring, computer floor tiles, or polished sealed concrete.

• Verify that the ceiling of the installation area is finished or treated to prevent particle

discharge.

• Verify that the installation area is well lit, and that the light source is uniformly

diffused without shadows. Adequate lighting should provide a comfortable reading

level and allow the identification of wire insulator colors without undue eye fatigue.

Lighting should be comparable to an office work environment, with a minimum level

of 21 meter/68.9 feet at each work surface. As a general rule, in a room with a 2.5

meters/8.2 feet ceiling, one 1.2 meters/4 feet fluorescent tube provides sufficient

illumination for 1.9-2.4 square meters/20.5-25.9 square feet.

• Verify that ventilation of the installation area is capable of maintaining an ambient

temperature of 0-40°C/32-104°F, and a relative humidity of 20-80% non-condensing,

while the system is operating. The maximum power rating of a KWS600v3 under full

load should not exceed 315W/1070 BTU/Hr. These figures are for each cabinet only,

and do not take into account heat generated by other equipment. In particular,

charging fully-discharged batteries may generate a considerable amount of heat,

depending on battery capacity and rate of charge. Refer to the equipment

manufacturer data for more information.

• Maximum distance between two KWS600v3 varies depending on material and

construction of buildings, but there must always be synchronization chains and radio

coverage overlap between the two KWS600v3 or handover between radio units. The

time it takes a person to cross the common coverage area must be 10 seconds or more,

as the handset needs time to scan for an alternative KWS600v3.

• Verify that the installation area is free of caustic or corrosive liquids, substances, or

materials. If batteries will be installed as part of the system, ensure that adequate

precautions are taken (such as special ventilation) to prevent corrosive emissions

from the batteries. Check local building codes for additional requirements.

• Verify that the installation area is located no closer than 6.1meters/20.0 feet from

electric devices that produce large electro-magnetic fields (EMF) or high levels of

radio frequency energy. Possible EMF sources are radio transmitters, electric arc

welding machines, copying machines, electric motors, refrigeration units, power

transformers, electric load centers, and main circuit breaker panels.